      <abstract>
        <p>核电管道系统运行中受热膨胀与振动作用，弹簧支吊架冷态调整载荷锁定值关联管道力学平衡与运行安全，锁定
值测算结合支吊架刚度、预压形态、管道自重及边界约束，依托力学模型剖析载荷分布，缓解管道运行初期应力集中与位移
偏移，测算环节处理非线性力学相关问题，研判支撑布局给管道整体稳定带来的作用，适配热膨胀引发的力学变动维持管道
支撑可靠状态。结合典型核电管道工况开展模拟测算，划定冷态调整载荷锁定值合理区间，校验数值对支吊架反力与管道应
力的调控作用，为核电管道系统安全运行筑牢基础。
关键词：核电管道；弹簧支吊架；冷态调整；载荷锁定；力学计算</p>