<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Article Authoring DTD v1.4 20240229//EN" "JATS-articleauthoring1.dtd">
<article article-type="research-article" xml:lang="zh-CN" xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">19</journal-id>
      <journal-title-group>
        <journal-title>医学研究</journal-title>
      </journal-title-group>
      <issn>2661-359X</issn>
      <publisher>
        <publisher-name>华文科学出版社</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.12421/yxyj2661-3603-2025-7-7-205</article-id>
      <article-id pub-id-type="publisher-id">15245</article-id>
      <title-group>
        <article-title>磁共振弥散张量成像技术在甲状腺相关性眼病活动性分期中的应用价值</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>黄超群 赵欢 张璐 马怿民* (新疆四七四医院 830000)</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>7</month>
      </pub-date>
      <issue>7</issue>
      <abstract>
        <p>目的：研究磁共振弥散张量成像（DTI）技术在评估 TAO 患者眼眶肌肉及软组织微观结构变化的作用。方法：本研究纳入 2024 年 2 月至 12 月期间接受 GE SIGNA Architect 3.0T 磁共振扫描仪扫描的 45 例 TAO 患者，随机分为实验组（23 例，活动期）和对照组（22 例，静 止期）。两组患者均接受 FA 值和 MD 值量化分析，借助影像软件精准定位眼眶肌肉与软组织区域，提取并记录 DTI 参数，分析 FA 值和 MD 值在不同分期的分布差异[1] 。结果：FA 值降低（1.2）的实验组患者比例为 43.48%，显著高于对照组的 18.18%，反映出活动期眼眶组织内水分扩散自由度增大， 组织松散。结论：磁共振弥散张量成像技术在 TAO 活动性分期中展现出较高的临床应用价值。</p>
      </abstract>
    </article-meta>
  </front>
</article>