      <abstract>
        <p>目的：依据标准方法 GB/T 42430-2023《血液、尿液中乙醇、甲醇、正丙醇、丙酮、异丙醇和正丁醇检验》，采用双柱双检测器顶空
气相色谱法对血液中乙醇含量的测定开展方法验证，评估本实验室是否有能力采用此标准方法对血液中的乙醇含量进行定性定量测定 1
。方
法：装有两根不同性状的毛细管色谱柱和两套氢火焰离子化检测器的顶空气相色谱仪，两根色谱柱做定性测定，单根色谱柱做内标标准曲
线法定量测定。验证内容：包括选择性、准确度、精密度、延迟效应、检出限和定量限、等。结果表明：经用不同性状色谱柱进行检测，
该方法能很好地对乙醇进行定性测定，选择性、准确度、精密度、线性范围、延迟效应和定量限均满足标准方法要求。因此，本实验室现
有技术能力满足标准方法的要求，能够按照标准方法 GB/T 42430-2023 进行血液中乙醇的定性定量检测。</p>
      </abstract>