      <abstract>
        <p>目的：探讨不同清洗方法应用于眼科精细复用器械的效果及安全性，为优化临床清洗流程提供参考。方法：选择 2025 年 1-4 月我院
眼科精细复用器械 200 件作为对照组，采用传统清洗方法；2025 年 5-8 月眼科精细复用器械 200 件作为观察组，采用传统清洗联合超声清
洗及酶清洗。结果：观察组器械污染物残留、锈蚀程度、器械变形程度显著低于对照组，器械管腔通畅性、完整性评分高于对照组（P＜0.05），
差异具有统计学意义。结论：传统清洗联合超声及酶清洗可有效降低污染物残留和生锈风险，显著提升管腔通畅性，同时保护器械完整性，
在清洗效果和安全性上均具有双重优势。</p>