        <article-title>职业卫生视角下的水泥厂窑尾粉尘综合治理系统设计：一种基于职业接触限值的工程控制方法</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>钱海洋 (镇江市疾病预防控制中心 江苏镇江 212000)</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>22</month>
      </pub-date>
      <issue>22</issue>
      <abstract>
        <p>目的:开发并验证一种以职业接触限值为导向的工程控制方法，用于设计水泥厂窑尾粉尘局部通风系统，从源头控制粉尘暴露，为尘
肺病的一级预防提供可复制的技术方案。方法:本研究以中国职业接触限值为核心设计约束，识别窑尾关键产尘点并评估其健康风险。结果
治理后，关键岗位的呼吸性粉尘浓度由 0.97-1.21mg/m³显著降至 0.37-0.49mg/m³，降幅达 52-69%，稳定低于中国职业接触限值（总尘：1mg/m
³；呼尘：0.7mg/m³）。结论:本研究提出将职业卫生标准直接转化为通风参数的方法，可有效降低作业场所粉尘与热负荷，从源头防控尘肺
病，具备行业推广价值。</p>