      <abstract>
        <p>本研究旨在评估基于等效均匀剂量（EUD）优化方法在肺癌容积旋转调强放疗技术（VMAT）中的应用价值。共纳入 35 例肺癌患者，每位
患者分别采用常规物理剂量-体积（DV 函数）和 EUD 函数优化计划，比较患侧肺、健侧肺及双肺的 V20、V5、平均剂量，心脏 V30、平均剂量，以及靶区相
关剂量学参数。在保证靶区覆盖相近的前提下，EUD 优化方法显著降低了正常组织的受照剂量，其中健侧肺低剂量区 V5改善尤为明显（DV 组：23.66±
6.7%，EUD 组：12.62±8.9%，P＜0.05）。靶区剂量学参数中，EUD 组均匀性指数（HI）略高于 DV 组，适形度指数（CI）和 PTV110%两组间无显著差异。结
论：基于 EUD 优化方法能够在不降低靶区适形度前提下，显著改善危及器官剂量分布，尤其显著改善健侧肺低剂量照射体积，从而获得生物学效应更优
的放疗计划。
【关键词】等效均匀剂量；肺癌；容积旋转调强放疗；物理优化</p>