<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Article Authoring DTD v1.4 20240229//EN" "JATS-articleauthoring1.dtd">
<article article-type="research-article" xml:lang="zh-CN" xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">20</journal-id>
      <journal-title-group>
        <journal-title>《预防医学研究》</journal-title>
      </journal-title-group>
      <issn>2705-0459</issn>
      <publisher>
        <publisher-name>环宇科学出版社主办；华文科学出版社主管</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">31065</article-id>
      <title-group>
        <article-title>超短眼轴白内障植入疏水丙烯酸单焦人工晶体术后显著近视漂移一例临床分析</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>任 静 成都市第五人民医院</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2026</year>
        <month>6</month>
      </pub-date>
      <issue>6</issue>
      <abstract>
        <p>目的 探讨眼轴长度（AL）＜21mm 的超短眼轴白内障患者人工晶体（IOL）度数测算，晶体选型与术后近视漂移的相关危险因素，总结
超短眼轴白内障手术 IOL 选度优化方案，规避屈光偏差并发症。方法 回顾 1 例 63 岁女性左眼老年性白内障病例，手术前采用 IOL=Master700 采集眼部
生物参数，应用 Barrett UniversalII、SRK/T、Haigis、Hoffer Q 四种公式测算 IOL 屈光值，手术中植入疏水泵烯酸单焦 IOL，术后进行规范主觉验光和
裂隙灯眼前节检查，统计实际屈光偏移数据，分析漂移诱因。结果 患者手术前左眼 AL=20.18mm，前方深度（ACD）=2.07mm，晶状体厚度（LT）=5.47mm。
手术前多公式测算显示+33.00D IOL 的理论预测残余屈光为-0.26～-0.38D，最后选用+33.00D。术后手术眼出现大幅近视漂移 2.25D，形成双眼明显屈光
参差。分析认为超短眼轴浅前房的解剖特点是术后近视漂移的核心诱因，白内障摘除后前房生理性加深、疏水丙烯酸 IOL 囊袋收缩造成有效晶体位置（ELP）
后移，放大了近视效应。结论 AL＜21mm 超短眼轴为术后近视漂移高危解剖类型，不建议以正视作为术后屈光目标；选择疏水丙烯酸 IOL 时需在多公式
平均测算度数基础上下调 0.25～0.50D，主动预留轻度远视对冲近视漂移；超短眼轴优先以 Barrett UninversalII 作为首选测算公式，多公式联合取低值
是降低屈光失误的关键手段。