      <article-id pub-id-type="doi">10.12361/2661-3549-07-05-0404</article-id>
      <article-id pub-id-type="publisher-id">15519</article-id>
      <title-group>
        <article-title>基于气象耦合注意力机制的 Transformer 电力负荷预测方法</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>王佳丽 （北京工商大学计算机与人工智能学院 北京房山 102488）</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>5</month>
      </pub-date>
      <issue>5</issue>
      <abstract>
        <p>电力负荷预测对智能电网调度与电力市场交易至关重要，其精度直接影响系统运行的经济性与可靠性。针对负荷序列的气象敏感性及传统 模型在长序列依赖建模、多变量非线性耦合及阈值效应等方面的不足，本文提出基于 Transformer 架构的气象敏感型负荷预测框架。模型通过气象 嵌入层与耦合注意力模块建模气象变量动态权重，采用双频位置编码捕捉负荷长期依赖与突变特征。实验表明，该模型在 72 小时历史窗口下的 MAE 为 0.0144，较 LSTM 降低 86.1%，能有效量化温度滞后效应和极端天气协同影响，为电网应对极端天气提供了可靠工具。</p>
      </abstract>