        <p>某石化公司 150 万吨/年渣油加氢装置的循环氢压缩机组采用串联式干气密封。2023 年 10 月发现干气密封高压端一级密封气泄漏量增大,且 呈现波动状态，影响机组平稳运行。在密封拆检过程中，发现一级密封面磨损，且有明显带液现象。分析了带液原因，并提出了预防措施，在应用 维护领域具备较强的参考意义。</p>