      <abstract>
        <p>机械排烟是建筑火灾发生后常用的排烟散热方式，其应用会使得火场特性发生改变。本文通过开展全尺寸实验，对比不同排烟条件对小室火灾的火场环境的影响，分析了实验过程中的烟气流动、室内温度以及 CO 浓度的变化趋势，探讨了机械排烟条件对人员疏散及灭火作战的影响。研究结果表明，机械排烟带来的降温效果比促进燃烧导致的升温更明显，但排烟口位置影响有毒气体浓度聚集，灭火救援行动应合力利用机械排烟系统。</p>