      <abstract>
        <p>地铁正线接触网供电分段的设置对运营安全至关重要。本文阐述了供电分段的形式和作用，分析了分
段绝缘器和绝缘关节两种方式的特点。比较了进站端、离变电所较近端和出站端三种供电分段设置方式的优缺
点。提出了增设绝缘关节与联络隔离开关的优化方案，并指出了实施中的注意事项。旨在为地铁供电系统的设
计与优化提供参考。</p>
      </abstract>