        <p>针对低合金钢（如 12CrMo、15CrMoG、 P11 等材质）小管径（DN50 以下）承插类角焊缝焊后热处理硬度检测合格率低的问题， 本文提出了三种改进施工方法。首先，通过优化加热绳缠绕方式（小碗绳贴合法兰侧面）确保均温区符合规范要求；其次，采用 10kW 履 带式加热器搭建小型加热炉，实现多道焊缝同步热处理，并通过热电偶精准控温；最后，通过增加焊缝层数，利用焊接自身热循环模拟回 火效应，分解淬硬组织。实际工程应用表明，上述方法显著提升了热处理后硬度检测合格率，兼顾施工效率与质量。</p>