        <p>为解决某 CO₂汽提法尿素装置中压系统因投运气相介质引发的剧烈波动问题，保障系统长周期稳定运行并挖掘节 能潜力，开展了系统的故障诊断与综合性技术改造。研究确认，不稳定根源在于原设计对气液两相流工况适应性不足，以及 设备材质防腐性能对运行氧浓度存在强依赖。为此，实施了三位一体改造：将核心设备材质升级为耐低氧腐蚀的双相不锈钢 2507；将中压系统由并联流程优化为串联流程以稳定物流分配；重构热能回收网络，高效回收利用自产蒸汽及甲铵冷凝反应 热。改造后，中压系统压力波动由±0.5 MPa 以上收窄至±0.05 MPa 以内，实现稳定投运。经物料衡算与热力学计算，系统 改造后每小时可回收利用热量约 2.52×10 8 kJ，经济效益显著，为同类装置的稳定运行与节能降耗提供了成功案例。</p>