        <p>LDAR 技术通过高精度检测设备定位和量化石化企业中挥发性有机化合物（VOCs）的泄漏
点，并依托数据分析和维修措施实现排放控制。研究以某化工企业为对象，采用 TVA-2020-FID 火
焰离子检测器对2294个密封点进行全面检测，发现20个点泄漏浓度超标，估算无组织排放量为1141.98
千克/年。通过对泄漏数据分类处理，结合排放因子和运行条件开展排放量核算，提出优先修复方案
并记录于标准化维修单中。维修后泄漏率显著下降，总排放量减少 668.24 千克/年，占维修前的 58.52%。</p>