      <abstract>
        <p>注射用水是药品生产过程中重要的原辅料，系统的稳定运行对于药品生产至关重要。注射用
水分配系统供水泵是注射用水系统重要的组成部分，是整个系统正常运行的关键部件之一。注射用水
分配系统泵的汽蚀现象给注射用水系统带来了潜在的质量风险，也成为了影响药品生产的一个不稳定
因素。找到注射用水分配系统泵汽蚀现象产生的根本原因是解除由此带来风险的基础条件。本文从注
射用水分配系统泵汽蚀现象入手，对注射用水分配系统泵汽蚀现象产生的原因做了详细分析，并对问
题形成的不同原因作了相应解决方案的阐述，为医药项目注射用水分配系统泵的汽蚀问题解决提供了
方案性参考。</p>
      </abstract>