      <title-group>
        <article-title>水电站厂房结构抗震性能数值模拟与优化设计</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>王胜群</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>10</month>
      </pub-date>
      <issue>10</issue>
      <abstract>
        <p>水电站厂房作为水利枢纽的核心建筑，其抗震性能直接决定了工程在地震灾害中的安全性与功能持续性。本文基于有限元理论，
以某坝后式水电站厂房为研究对象，构建精细化三维数值模型，采用时程分析法与 Pushover 分析法耦合的手段，系统研究结构在强震作用
下的动力响应规律，识别抗震薄弱区域，并通过多目标优化算法实现结构抗震性能与经济性的协同提升。研究表明：厂房结构在水平地震
作用下呈现"上柔下刚"的响应特征，主机室楼层梁端与柱节点为典型薄弱部位；通过优化梁柱截面尺寸、增设耗能支撑及节点强化处理，
可使结构最大层间位移角降低 28.3%，节点最大应力降低 31.7%，且经济性指标控制在合理范围。研究成果为高烈度地震区水电站厂房的抗
震设计提供了量化依据与技术路径。
关键词：水电站厂房；抗震；优化设计</p>