      <title-group>
        <article-title>ICP-MS 法测定活性焦重金属及环境风险评估研究</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>钟 琪</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>14</month>
      </pub-date>
      <issue>14</issue>
      <abstract>
        <p>本文研究了利用电感耦合等离子体质谱法（ICP-MS）测定活性焦中铅（Pb）、镉（Cd）、铬（Cr）、铜（Cu）、锌（Zn）、镍（Ni）
六种重金属元素的含量，并对其环境风险进行了评估。通过优化样品前处理方法、仪器参数设置及干扰消除策略，提高了检测的准确性和
可靠性。实验结果表明，该方法回收率在 90%-110%之间，相对标准偏差（RSD）在 1%-5%之间，具有较高的精密度和准确度。基于检测
结果，本文对活性焦中重金属的环境风险进行了初步评估，为活性焦的安全应用提供了科学依据。
关键词：ICP-MS 法；活性焦；重金属测定；环境风险评估；样品前处理</p>