      <abstract>
        <p>本文聚焦于广州地铁 22 号线的盾构渣土处理系统，将其作为核心研究对象，深入剖析环保节能举措给盾构设备维修保养带来的影
响机制。研究过程中，详细分析了渣土减量化处理、水循环利用以及资源化再生等一系列技术的实际应用成效，进而揭示出这些环保措施
在设备磨损状况、维护周期设定以及能耗管理方式等方面所产生的具体影响。基于上述研究，本文创新性地提出了“预防性维护-动态监测
-资源循环”三位一体的优化策略。为验证该策略的可行性与有效性，将其与广州地铁 22 号线的实际工程相结合进行实践检验。实践结果
表明，此策略在降低设备故障发生率、缩减维修成本支出以及提升环保综合效益等方面均取得了显著成效。该研究成果能够为地铁盾构施
工向绿色化方向转型提供切实可行的技术参考依据。
关键词：地铁盾构；渣土处理；环保节能；维修保养；资源循环</p>