      <abstract>
        <p>在全球“双碳”战略推进背景下，建筑行业作为能源消耗与碳排放的核心领域，其节能转型迫在眉睫。暖通空调系统作为建筑能
耗的主要载体，占公共建筑总能耗的 40%～60%，其施工阶段的节能技术应用直接影响系统全生命周期能效与碳减排成效。本文基于碳中和
目标导向，系统梳理暖通空调施工节能的核心价值与行业现状，从冷热源系统优化、输配系统提质、末端系统升级、智能管控集成四大维
度，构建全流程施工节能技术路径体系，结合施工全过程管控要求提出保障措施，并通过案例验证技术可行性。研究表明，科学整合高效
设备应用、精细化施工工艺与智能管控技术，可使暖通空调系统综合能效比提升 30%以上，年碳减排量降低 15%～25%，为建筑行业践行碳
中和目标提供关键技术支撑。
关键词：碳中和；暖通空调；施工节能；技术路径；智能管控</p>