      <abstract>
        <p>严寒地区农村住宅围护结构热工性能薄弱、能耗水平偏高，尤其南向窗墙比作为影响太阳得热与传热损失的重要因素，对冬季采
暖能耗具有显著影响。本文以张家口严寒地区典型农宅为研究对象，基于 Rhino7 与 Ladybug Tools 平台构建建筑能耗模型，设置不同南向
窗墙比参数，对冬季采暖能耗进行模拟分析。在满足绿色建筑节能标准的前提下，通过优化围护结构构造与门窗性能，探讨南向窗墙比与
采暖能耗之间的变化规律，并提出合理优化区间。研究结果表明：南向窗墙比存在能耗拐点，当窗墙比过低时太阳得热不足，过高时传热
损失增大；在满足围护结构 K 值规范的条件下，优化后的南向窗墙比可有效降低采暖能耗。研究成果可为严寒地区农宅节能设计提供理论
依据与技术参考。
关键词：严寒地区；农村住宅；窗墙比；采暖能耗；建筑节能优化</p>