        <p>结构质量评定工作中，混凝土抗压强度检测是重点手段，但是试件制备、养护条件、设备精度及操作手法等因素常使得检测结果
偏离真实值，本文围绕建筑工程材料检测中混凝土试件抗压强度测试的误差成因展开系统地分析，针对试件尺寸偏差、养护环境失控、加
载速率不稳、人为读数误差四个维度分析问题机理，给出标准化振捣成型、智能温湿度调控、伺服加载控制、数字图像识别四项技术工法，
并融合某框架剪力墙结构高层住宅工程说明详细应用流程。实践证明，所提技术可将检测误差控制在规范允许范围内，给造价咨询企业成
果文件编制给予可靠的数据支撑。
关键词：混凝土抗压强度；检测误差控制；试件制备工艺；加载速率控制</p>