        <p>研究一种将低屈服点钢筋配置于连梁跨中的耗能连梁，以实现损伤集中与震后可更换。在 ABAQUS 中建立低屈服点钢筋的滞回模
型并验证；将该模型应用于高层剪力墙结构，进行罕遇地震下的弹塑性时程分析；以普通连梁为参照，研究耗能连梁替换刚度比对减震效
果的影响。结果表明：所建模型能较好反映低屈服点钢筋的耗能特性；采用该耗能连梁可显著减小结构层间位移角和基底剪力；替换刚度
比取 0.4 时减震效果最优。
关键词：低屈服点钢筋；耗能连梁；替换刚度比；剪力墙结构；减震设计</p>