        <p>本文以集中供暖二次管网为研究对象，对管网结构和常规调控方式进行梳理，分析运行中的主要问题，从供回水温度、泵组参数、
水力平衡、供回水温差等几个方面开展多参数优化研究，制定出标准化的调控方案。根据实际工况对节能效果进行量化测算，分析能耗约
束机制并进行经济性分析。结果表明精细化调控可以有效地降低输配能耗和热损耗，节能和经济效益较好，可以为二次管网节能改造和精
细化运维提供技术支撑。
关键词：集中供暖；二次管网；参数优化；水力平衡；节能潜力；泵耗控制</p>