        <article-title>某 1000MW 机组定冷水流量低跳闸原因分析与调整策略</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>李 昭 徐田欣 （湖南华电平江发电有限公司 湖南岳阳 414513）</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2024</year>
        <month>14</month>
      </pub-date>
      <issue>14</issue>
      <abstract>
        <p>本文介绍了发电机定冷水系统的构成。针对某 1000MW 机组在定冷水电加热器检修后，对该电加热器注水操作的过程中，突发定
冷水流量大幅下降，导致定冷水流量低保护动作的故障，分析了该故障的原因[1]，根据机组实际情况增设了一个定冷水箱用于增加系统水容
积，并增设对应补水管路，并将定冷水流量计进行位置更换。通过对定冷水进行改造，有效降低了定冷水加热器投退时对系统的扰动，提
高了定冷水系统稳定性[2]
。
关键词：定冷水；流量低保护；上汽百万机组</p>