      <abstract>
        <p>针对佛山地铁 2 号线列车按压电笛按钮松开后电笛长鸣无法停止的问题，对电笛按钮进行了故障排查，分析了电笛按钮触点粘连
无法分断的原因。结合电路原理，通过加装接触器的方式对电笛控制电路进行了重新设计优化，整改后列车电笛长鸣无法停止的故障得到
了全面消除，为业内其他地铁同行运营维保工作及地铁车辆电笛控制电路设计提供了有价值的参考。
关键词：地铁车辆；电笛；按钮故障；触点粘连；故障分析</p>