        <article-title>浅析配电线路单相断线故障检测</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>陈小聪 杨梦华</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2024</year>
        <month>9</month>
      </pub-date>
      <issue>9</issue>
      <abstract>
        <p>本文针对线路发生单相断线故障，利用对称分量法与复合序网对电流量进行故障分析。得到故
障后相电流与序电流变化特征，并与 TA 断线时电流变化特征进行比较。分析了 10KV 配电的线路出现断
路故障的原因以及 10KV 配电线路单相断线的故障检测与定位。</p>